Custom Search
 
  
 
TM 55-1905-220-14-3
Table 3-19.
Hydrostarter - Fluid Emerges from the Reservoir Filler
Cap When Starter is Used - Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Fluid emerges from the reservoir filler cap when starter is used.
Step 1.
Check for filter element in filler cap loaded with dirt.
Rinse the filler cap thoroughly in fuel oil and dry it with compressed air.
Step 2.
Check for nitrogen in fluid returned to reservoir. Overhaul the accumulator. See
Step 3.
Check for excess fluid in reservoir.
Check the fluid level when the accumulator is empty. The fluid level should be
approximately 2-1/2 inches (6.4 cm) from the top of the tank.
Table 3-20.
Hydrostarter - Fluid Emerges Around Rubber Boot of Hand Pump - Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Fluid emerges around rubber boot of hand pump.
Step 1.
Check for damaged piston seal rings.
Replace the seal rings and leather back-up rings on the pump piston. Refer to
paragraph 3-49.
3-73


 