Tweet |
Custom Search
|
|
|
||
TM 55-1905-220-14-3
Table 3-23.
Generator Engine - Hard Starting Troubleshooting.(Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
Low compression (Cont).
Step 4.
Check for improper valve clearance adjustment.
Adjust the exhaust valve clearance. Refer to paragraph 3-90.
Step 5.
Check for blower not functioning.
Inspect the blower drive shaft and drive coupling. Refer to paragraph 3-61.
5.
Inoperative starting aid at low ambient temp.
Check for improper operation of fluid starting aid. Operate the starting aid. Refer
to paragraph 2-39.
3-83
|
||