TM 55-1905-220-14-3
Table 3-25.
Generator Engine - No Fuel or Insufficient Fuel
Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
Faulty fuel pump.
Step 1.
Check for relief valve not seating.
Perform a Fuel Oil Test and, if inadequate, clean and inspect the valve seat
assembly. Refer to paragraphs 3-69.
Step 2.
Check for worn gears or pump body.
Replace the pump, refer to paragraph 3-69.
Step 3.
Check for fuel pump not rotating. Check the condition of the fuel pump drive and
blower drive and replace defective parts. Refer to paragraphs 3-66, 3-68 and 3-69.
4.
Faulty installation.
Step 1. Check for restricted fitting missing from return line.
Install a restricted fitting elbow in the return line.
3-98
|
||