Custom Search
 
  
 
TM 55-1905-220-14-3
Table 3-31.
Hydrostarter - Low or No Accumulator Pressure
Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Engine driven pump fails to raise pressure (Cont).
e. If the accumulator pressure does not rise, make certain that the hand pump
relief valve (3) is closed after the pressure is released and repeat the above
purging procedure.
Step 2.
Check for low fluid level.
The fluid level in the reservoir must be sufficient to completely cover the screen at
the bottom of the tank after the accumulator is charged and the engine-driven
pump is by-passing a full stream of fluid to the reservoir.
3-113


 