TM 55-1905-220-14-3
Table 3-36.
Hydrostarter - Starter Turns but Engine Does Not
Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Starter turns but engine does not - troubleshooting.
Step 1.
Check for pinion not engaging in flywheel ring gear.
Replace as per paragraph 3-101. Refer to Direct Support Maintenance.
Step 2.
Check for broken bendix drive.
Replace Bendix drive. Operator should disengage hydrostarter as soon as engine
starts. Prolonging the period during which clutch overruns will reduce clutch life.
Table 3-37.
Hydrostarter - Loss of Accumulator Precharge
(Nitrogen) Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Loss of accumulator precharge (nitrogen).
Step 1.
Check for damaged seal ring on piston.
With some nitrogen precharge but no fluid pressure in the system, bubbles and
foaming in the reservoir indicate that the nitrogen is leaking past the seal ring on
the accumulator piston. Refer to Direct Support Maintenance.