Tweet |
Custom Search
|
|
|
||
TM 55-1905-220-14-3
Table 3-51. Anchor Winch Torque Converter Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
Excessive pressure.
Step 1.
Inspect for stuck piston in relief valve of charging pump.
Refer to Direct Support Maintenance.
NOTE
The pressure and temperature gauges provide the operator with a constant check on converter
operation. Immediate recognition of an abnormal reading may prevent a breakdown. It is
important, therefore, whenever a gauge is found to be faulty it be immediately replaced.
Table 3-52. Anchor Winch - Hydraulic Tank Balanced
Piston Relief Valves Troubleshooting.
NOTE
Refer to paragraph 3-137 for all maintenance procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Erratic Pressure.
Step 1.
Check for foreign matter in system.
Drain, flush and refill system with clean fluid.
Step 2.
Inspect for a worn piston or seat in cover.
Replace piston and seat.
Step 3.
Inspect for piston sticking in body or cover.
Clean piston. Remove burrs by light lapping. Check freedom of movement on reassembly.
Replace if necessary.
3-158
|
||