Table 3-68. Anchor Winch Engine Low or No Accumulator
Pressure Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Engine driven pump fails to raise pressure (Cont).
Step 2.
Check for low fluid level.
The fluid level in the reservoir must be sufficient to completely cover the screen at the
bottom of the tank after the accumulator is charged and the engine-driven pump is by-
passing a full stream of fluid to the reservoir.