3-9.3. EMERGENCY SHUTDOWN HEAD & LINKAGE - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
Installation (Cont)
k. Cable
Position so that notch on
clamp
cable is in clamp.
(16)
l. Cap screw
Tighten.
(15) and
nut (14)
m. Handle
Install.
(9)
n. Nut (10)
Secure.
and han-
dle (9)
o. Cable
Install on cable (20).
clamp
(8)
p. Cap screw
Install in cable clamp
(7)
(8) and secure.
q. Nut (5)
Install on cable (20).
r. Ball
Install on cable (20).
joint
(6)
s. Nut (5)
Jam against ball joint (6).
t. Ball
Install in air intake
joint
latch.
(6)
u. Lockwash-
Secure cable clamp to
er (4),
bracket
cable
clamp
(8),
screw (3)
v. Lockwash-
Secure ball joint (6).
er (2)
and nut
(1)