TM 55-1905-220-14-4
3-9.4. WATER TEMPERATURE SWITCH - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
Adjustment
6. Water
a. Adjusting
a. Adjust.
Adjust so that
tempera-
screw (5)
the points
ture alarm
close at 205
5F (96.1
switch
2.7 ).
C
b. Jumper
b. Remove.
wire
c. Cover
c. Replace.
(2), and
screw
(1)
Removal
7. Water
a. Screw (1)
Remove.
tempera-
ture alarm
b. Cover (2)
Remove.
switch
c. Wiring
Disconnect.
d. Screws
Remove.
(6) and
lockwash-
ers (7)
e. Switch
Remove.
(8)
f. Capillary
Remove.
tube (9)
3-394


 