Tweet |
Custom Search
|
|
|
||
TM 55-1905-220-14-4
3-10. VARIABLE SPEED MECHANICAL GOVERNOR - MAINTENANCE INSTRUCTIONS (Cont).
This task covers:
a. Inspection
c. Installation
e. Adjustment
b. Removal
d. Repair
INITIAL SETUP :
Test Equipment
References
NONE
NONE
Equipment
Special Tools
Condition
Condition Description
Plastic hammer
Rocker Arm Covers
Torque wrench
Fuel Pump
Material/Parts
Special Environmental Conditions
Gasket kit P/N 5196375
NONE
Personnel Required
General Safety Instructions
1
NONE
LOCATION
ITEM
ACTION
REMARKS
Inspection
1. Governor
a. Linkage
Inspect for wear, damage,
or loose components.
b. Hoses
Inspect for leaks,
cracks, and loose hose
clamps.
c. Housing
Inspect for leaks, or
external damage.
d. Solenoid
Inspect for defective
wiring, wear, or damage.
3-404/(3-405 blank)
|
||