3-11.2. AIR INTAKE HOUSING - MAINTENANCE INSTRUCTIONS.
An air intake housing is mounted on each blower. Each housing contains a shutdown valve. The shutdown
valve shuts off the air supply and stops the engine when abnormal operating conditions require an emergency
shutdown. The two air intake housings are connected together and to the emergency shutdown station. After
an emergency shutdown, the shutdown valves must be reset.
This task covers:
a. Inspection
c. Repair
e. Adjustment
b. Removal
d. Installation
INITIAL SETUP :
Test Equipment
References
NONE
NONE
Equipment
Special Tools
Condition Condition Description
Torque Wrench
Air silencer removed
Material/Parts
Special Environmental Conditions
Gasket kit P/N 5196375
NONE
Gasket kit P/N 5196386
Personnel Required
General Safety Instructions
1
Use eye protection when using
compressed air.
LOCATION
ITEM
ACTION
REMARKS
Inspection
1. Air
a. HousingInspect for cracks,
intake
breaks and damage.
b. LinkageInspect for binding,
defective parts, damage
and loose parts.