Custom Search
 
  
 
TM 55-1905-220-14-4
3-24. INSTRUMENT PANEL-MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
3. Water
a. Clip (7)
Remove.
tempera-
ture
b. Adaptor
Remove.
gage
(8)
c. Nuts (9),
Disassemble.
lockwash-
ers (10)
and gage
clamp (11)
d. Gage (12)
Remove.
e. Gage (12)
Install.
f. Gage
Assemble.
Incorrect cool-
clamp
ant temperature
(11),
readings will
nuts
be registered
(9)
if the gage
and
assembly is in-
lock-
correctly in-
washers
stalled or the
(10)
capillary tube
is damaged.
g. Clip (7)
Install.
To prevent dam-
age to the gage
assembly from
vibration, the
capillary tube
must be secure-
ly fastened to
engine the full
length with
suitable clips
at intervals of
ten inches or
less. Sharp
bends in tube
must be avoided,
particularly at
gage or bulb
connection
areas.. Where
tube must be.
3-622


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business