TM 55-1905-220-14-4
3-46. HYDROSTARTER - MAINTENENCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION
1. Hydro-
Hydro-
a. Check for leaks,
starter
starter
cracks, dents or wear.
b. Check inlet and outlet
connections for leaks.
REPLACEMENT
2. Hand pump
Bleeder
Release the oil
screw
pressure in the hoses
and accumulator by
opening the bleeder
screw on the side
of the hand pump
approximately 1/2 turn.
WARNING
The oil pressure in the system must be released prior to servicing the
hydrostarter or any other components on the system to prevent possible injury to
personnel or equipment.
3. Hydraulic
a. Inlet
Disconnect from hydro-
hoses
hoses
starter.
b. Outlet
Disconnect from hydro-
hose
starter.
3-905