TM 55-1905-220-14-4
3-52.2. HYDROSTARTER SUCTION FILTER - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
SERVICE
2. Hand pump
Bleeder
Release the pressure in
screw valve
the hydrostarter system
by opening the bleeder
screw valve on side of
pump approximately 1/2 turn.
WARNING
The oil pressure in the system must be released prior to servicing the filter or
any other components of the system to prevent possible injury to personnel or
equipment.