Custom Search
 
  
 
TM 55-1905-220-14-4
3-55. SHAFT INFLATABLE SEAL - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
INFLATION (Cont)
WARNING
If inflatable sealing ring does not inflate STOP IMMEDIATELY .  DO NOT
PROCEED. Failure of inflatable sealing ring to inflate can cause loss of life and
loss of the landing craft. Check carbon dioxide, (CO ) tank is it full? Try CO2 tank
2
from aft or Forward engine room. If Inflatable sealing ring still does not inflate
STOP - DO NOT PROCEED. Contact General Support Maintenance AT ONCE.
DEFLATION
12. Inflat-
a. Carbon
Close CO2 valve (1).
able
dioxide
Turn counter-clockwise.
housing
tank
ring
(CO2)
b. Pressure
Pressure will drop in
gage
pressure gage (9).
3-987/(3-988 Blank)


 