3-56. SHAFT SEALS - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
Installation (Cont)
EDGES NOT MATED, COMPLETELY MIS-ALIGNED. WHEN
THESE EDGES INTERFACE WITH HOUSING WALL, THE MIS-
ALIGNED AREA, HOWEVER SLIGHT, FORMS A LEAK PATH.
ALIGNMENT OF
SEALING ELEMENT
IN LIKE MANNER, IF MIS-ALIGNMENT OCCURS WHEN THE
HOUSING HALVES ARE PUT TOGETHER, LEAKAGE ALSO
OCCURS.
Be sure ALL surfaces are in perfect alignment. If not,
completely separate and repeat procedures.
4. Hold sealing element (27) in shaft for 20 to 30 seconds
to allow the cement to partially
set up.