Tweet |
Custom Search
|
|
|
||
TM 55-1905-220-14-5
3-62.1. GENERATOR (12VDC)-MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION (Cont)
c.
Wiring
1. Inspect external wiring
for wear, breaks or
fraying.
2. Check for tight, exter-
nal electrical connec-
tions.
d. Brushes
1. Remove protective
cover and inspect
for wear and broken
brushes or springs.
2. With the engine run-
ning, inspect for
excessive sparking.
3-1071
|
||