TM 55-1905-220-14-5
3-65.3.2. WATER TEMPERATURE ALARM SWITCH - MAINTENANCE INSTRUCTIONS
(Cont).
LOCATION
ITEM
ACTION
REMARKS
TESTING (Cont)
b. Gate
1. Open valves.
Valves
2. Restart the engine
immediately without
load. Run the engine
until the engine cools
down.
4955-123
REMOVAL
3.
Alarm
a. Screw
Remove.
switch
(4)
b. Cover
Remove.
(5)
c.
Wiring
Disconnect.
d. Screws
Remove.
(6) and
lock-
washers
(7)
e. Switch
Remove.
(8)
3-1158