Custom Search
 
  
 
TM 55-1905-220-14-5
3-65.3.3. FUEL OIL PRESSURE ALARM SWITCH - MAINTENANCE INSTRUCTIONS.
This task covers:
a. Testing
c.
Removal
b. Adjustment
d.
Installation
INITIAL SETUP
Test Equipment
References
Jumper wire
NONE
Equipment
Special Tools
Condition
Condition Description
Fuel oil pressure
Para
gage
NONE
Material/Parts
Special Environmental Conditions
NONE
NONE
Personnel Required
General Safety Instructions
1
NONE
LOCATION
ITEM
ACTION
REMARKS
TESTING
1.
Fuel
a. Pipe
Remove.
filter
plug
outlet
(1)
b. Pressure
Install.
gage
(2)
3-1160


 