Custom Search
 
  
 
TM 55-1905-220-14-5
3-67. AIR INTAKE - MAINTENANCE INSTRUCTIONS.
The air intake shut-down housing, mounted on the side of the blower, serves as a mounting for the air
cleaner. The air shut-down housing contains an air shut-down valve that shuts off the air supply and stops the
engine whenever abnormal operating conditions require an emergency shut-down.
This task covers:
a.
Inspection
c.
Removal
e.
Repair
b.
Service
d.
Disassembly
f.
Installation
INITIAL SETUP
Test Equipment
References
NONE
NONE
Equipment
Special Tools
Condition Condition Description
Para
Torque wrench 0-50 ft. lb.
3-71.  Air Cleaner Removal
3-65.1. Disassembly Emergency
Shutdown Linkage
3-65.2. Disassembly Shutdown
Material/Parts
Special Environmental Conditions
Repair Kit P/N 5193113
NONE
Oil MIL-L-2104 Type
OE/HDO-10
Personnel Required
General Safety Instructions
1
Observe all WARNINGS
LOCATION
ITEM
ACTION
REMARKS
INSPECTION
1.
Air in-
a.  Shut-
Inspect for binding.
Lubricate if
take
down
Disconnect latch from
binding, or re-
valve
ball joint and link.
place if re-
shaft
Move latch manually.
quired.
3-1204


 


Privacy Statement - Copyright Information. - Contact Us