Custom Search
 
  
 
TM 55-1905-220-14-5
3-75. FRESH WATER PUMP - MAINTENANCE INSTRUCTIONS Cont.
LOCATION
ITEM
ACTION
REMARKS
REPLACEMENT Cont.
d. Fresh
1. Remove bolts (12) and
Use J 4242,
water
seal washers (13).
wrench, to
pump
loosen bolts.
2. Remove fresh water
pump (14) from blower.
3. Remove gasket (15).
Discard.
INSPECTION
4.
Fresh
a. Outlet
1. Place the outlet
water
flange
flange (10) on fresh
pump
water pump outlet
(11).
2. Slip outlet packing
Use repair kit,
(9) over fresh water
P/N 5193605.
pump outlet (11).
b. Fresh
1. Install gasket (15).
Use repair kit,
water
P/N 5193605.
Pump
2. Place fresh water pump
Align and mesh
(14) against the
lugs on the
blower end plate.
drive coupling
with the lugs
on the inter-
mediate shaft coupling.
3. Install seal washers
Tighten, secure
(13) and bolts (12).
to the blower.
3-1320


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business