3-99. INSTRUMENT PANEL - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
6. Water tem-
a. Clip
Remove.
perature
(27)
gage
b. Adaptor
Remove. (28)
c. Nuts
Disassemble.
(29),
lock-
washers
(30) and
gage
clamp
(31)
d. Gage
Remove.
(32)
e. Gage
Install.
(32)
f. Gage
Assemble
Incorrect cool-
clamp
ant temperature
(31),
readings will
nuts
be registered
(29) and
if the gage
lock-
assembly is
washers
incorrectly in-
(30)
stalled or the
capillary tube
is damaged.
g. Clip
Install
To prevent dam-
(27)
age to the gage
assembly from
vibration, the
capillary tube
must be secure-
ly fastened to
the engine the
full length
with suitable
clips at inter-
vals of ten
inches or less.