Custom Search
 
  
 
TM 55-1905-220-14-5
3-101. HYDROSTARTER - MAINTENANCE INSTRUCTIONS.
a. The hydrostarter (starting) motor is mounted on the flywheel housing. The hydrostarter has a high
rate of acceleration; therefore, the engine is cranked faster than other starting systems.
b. An overrunning clutch protects the starting motor at all times from being driven at high speeds by the
engine before disengagement of the pinion.
This task covers:
a. Inspection
b. Replacement
c. Repair
d. Installation
INITIAL SETUP
Test Equipment
References
NONE
Refer to paragraph 3-105 for for-
ward engine room piping and to
paragraph 3-106 for aft engine
room piping.
Equipment
Special Tools
Condition Condition Description
Para
NONE
NONE
Material/Parts
Special Environmental Conditions
Teflon tape
NONE
Personnel Required
General Safety Instructions
2
Observe WARNINGS in this
procedure.
LOCATION
ITEM
ACTION
REMARKS
INSPECTION
1. Hydro-
Hydro-
a. Check for leaks,
starter
starter
cracks, dents or wear.
b. Check inlet and outlet
connections for leaks.
c. Check gasket for leaks.
3-1750


 


Privacy Statement - Copyright Information. - Contact Us