TM 55-1905-220-14-5
3-107.1. HYDROSTARTER RESERVOIR - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
SERVICE (Cont)
Wear eye protection when using compressed air.
c. Clean strainer screen
Clean in fuel
(4).
oil and dry
with compressed
air.
d. Clean reservoir (1) by
flushing out the old
hydraulic fluid.
REPLACE
6.
Reservoir
a. Place suitable contain-
(1)
er under drain plug
(3).
b. Turn drain plug (3)
counter-clockwise to
remove.
c. Drain hydraulic oil
into a suitable con-
tainer.
d. Disconnect return pip-
ing (5).
e. Disconnect supply pip-
ing (6).
f. Disconnect relief pip-
ing (7).
g. Remove nuts (8), lock-
washers (9) and cap-
screws (10) from brac-
kets (11).
h. Remove reservoir (1)
from its mountings.
3-1796