Tweet |
Custom Search
|
|
|
||
TM 55-1905-220-14-5
3-107.3. HYDROSTARTER SOLENOID - MAINTENANCE INSTRUCTIONS . (Cont).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
8.
a. Disconnect electrical
housing
connections.
b. Remove screws (1) and
lockwashers (2).
c. Remove from mount.
REPAIR
9.
Repair.
Refer to Direct
housing
Support Mainten-
ance.
10.
Manual
a. Loosen wing nut (3).
control
screw
b. Unscrew manual control
screw (4) from solenoid
housing (5).
c. Remove lockwasher (6).
d. Remove wing nut (3).
e. Remove seal ring (7)
Discard seal
from manual control
ring.
screw (4).
11.
Manual
a. Install new seal ring
control
(7) on manual control
screw
screw (4).
(4)
b. Replace wing nut (3)
on manual control
screw (4).
c. Install manual control
screw (4) into solenoid
housing (5) and lock-
washer (6).
d. Tighten wing nut (3).
3-1806
|
||