Custom Search
 
  
 
TM 55-1905-220-14-5
3-108. 24 VDC RECTIFIER-MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
Make sure all sources of power are shutoff. Tag
and disconnect all incoming AC wiring, and outgoing
DC wiring. Failure to do so may result in severe
injury to personnel, and damage to landing craft.
1. Loosen screws (1) on
Door will swing
front panel (2).
open on hinge.
2. Tag and disconnect
Refer to sche-
wiring from ammeter
matic.
(9).
3. Remove hardware at-
Replace if de-
taching ammeter (9)
fective.
to door.
4. Install ammeter (9).
5. Attach wiring and re-
move tags to ammeter
(9).
6. Close front panel door
(2) and tighten screws
(1).
REMOVAL
Make sure all sources of power are shutoff. Tag
and disconnect all incoming AC wiring, and outgoing
DC wiring. Failure to do so may result in severe
injury to personnel, and damage to landing craft.
3. 24 VDC
Rectifier
1. Loosen screws (1) on
Door will swing
rectifier
assembly
front panel (2).
open on hinge.
2. Tag and disconnect
Refer to sche-
external wiring to
matic.
rectifier assembly.
3. Remove screws (10).
3-1816


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business