Tweet |
Custom Search
|
|
|
||
TM 55-1905-220-14-6
3-120. WINCH BRAKE AND MOTOR - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
10. Mag-
a. Run wiring (7) thru conduit (9).
netic
assem-
b. Connect wiring (7) to magnetic
bly (8)
coil on magnetic assembly (8)
as follows:
CAUTION
The sequence of black and yellow leads is important. DO NOT
INVERT COILS. Specify voltage, phase and frequency stamped on
brake nameplate.
Single Phase
High voltage - Connect black lead of one coil to yellow lead of other
coil and connect remaining two leads to power supply.
3-2028
|
||