Custom Search
 
  
 
TM 55-1905-220-14-6
3-143. AIR INTAKE - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (Cont)]
7.
Emergency
Cable and
Refer to para-
shutdown
linkage
graph 3-141.1.
8.
Shutdown
Linkage
Install.
Refer to para-
and
graph 3-141.2.
bracket
9.
Air
a. Capscrew
Tighten.
Torque cap
intake
(5),
screws evenly
and
to 16-20 lb.
those
ft. (21.8 to
from
27.3 Nm).
para-
graph
b. Air
Install.
cleaner
mounting
tube
(1)
c.  Air
Check by starting and
intake
running the generator
housing
engine at idle speed and
(4)
no load. Trip the air
shutdown. If the engine
does not stop, check for
air leakage between the
shutdown valve (13) and
the striker plate (5).
Reposition valve as
necessary.
d. Air
Install.
See paragraph
cleaner
3-156.
3-2430


 