TM 55-1905-220-14-7
3-171.2. CONNECTING ROD - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
REASSEMBLY (Cont)
2. Insert installer in
Use installer
bushing, then insert
tool J1513-6,
handle in the instal-
and handle
ler.
tool J1513-2.
3. Drive the bushing in
until the flange of
the installer bottoms
on the connecting rod.
c. Connecting
Turn the connecting rod
rod
over in the holder and
(3)
install the second bush-
Ing in the same manner.
NOTE
The bushings must withstand an end load of 2000 pounds (907
kg) without moving after installation.
13. Bushing
a. Connecting Assemble.
rod
(3),
bolts
(4),
bearing
cap
(2),
and
nuts
(1)
3-2910