Custom Search
 
  
 
TM 55-1905-220-14-7
3-180.1. HYDROSTARTER RESERVOIR - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION
7.
Reservoir
a. Replace reservoir (1).
(1)
b. Install brackets (11),
nuts (8), lockwashers
(9), and capscrews
(10).
c. Install strainer
screen (4).
d. Install drain plug
(3).
e. Connect supply piping
(6).
f.
Connect return piping
(5).
g. Connect relief piping
(7).
h. Fill reservoir with
Reservoir cap-
hydraulic fluid (MIL-
acity is 7.5
L-17672, Type 2135
gallons (28.4
TH).
liters).
i.
Replace and tighten
breather ventilator
cap (2).
j.
Check all fittings
and plugs for leaks.
3-3042


 