Tweet |
Custom Search
|
|
|
||
TM 55-1905-220-14-7
3-208. DIRECTIONAL CONTROL VALVE - MAINTENANCE INSTRUCTIONS
(Continued)
LOCATION
ITEM
ACTION
REMARKS
DISASSEMBLY (Cont)
d. Solenoid
Remove.
Discard gasket.
mounting
plate
(14),
and
gasket
(10)
e. Screw
Remove.
(15)
f.
Adapter
Remove.
Discard gasket.
plate
(16),
and
gasket
(17)
g. Retaining
Remove.
Discard "O"
ring
rings.
(18),
spring
guide
(19),
"0 "
rings
(20
and
21),
washers
(22),
spring
(23),
and
spring
washers
(24)
NOTE
To help remove retaining ring (18), apply force to the end of the
push pin (25) located in the opposite end of the valve.
3-3226
|
||