TM 55-1905-220-14-7
3-209. HYDRAULIC CUB PUMP UNIT - HYDRAULIC RESERVOIR TANK AND STRAINER
MAINTENANCE INSTRUCTIONS.
LOCATION
ITEM
ACTION
REMARKS
SERVICE
2. Hydraulic
a. System
1. Operate until oil
system
is warm.
2. Stop operation.
3. Remove oil from
Drain oil into
reservoir.
a suitable
container.
b. Access
Loosen screw and remove
plate
plate.
(1)
WARNING
Wear protective eye goggles when using compressed air.
c. Strainer
Remove and clean.
Clean with fuel
(2)
oil and blow
dry with com-
pressed air.
d. Reservoir
Clean.
(3)
e. Filter
Remove and clean.
Clean with fuel
breather
oil and blow
(4)
dry with com-
pressed air.
f.
Strainer
Reinstall.
(2)
g. Access
Reinstall.
plate
(1
h. Filter
Refill.
The reservoir
pipe
holds 10 gal-
(5)
lons (37.85
liters) of
hydraulic fluid.
3-3234