Custom Search
 
  
 
TM 55-1905-220-14-7
3-209. HYDRAULIC CUB PUMP UNIT - HYDRAULIC RESERVOIR TANK AND STRAINER
MAINTENANCE INSTRUCTIONS.
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION
5.
a. Reservoir
Install.
(3),
screws
(10),
and
nuts
(9)
b. Two
Install.
manifold
fittings
(8),
eight
screws
(6),
and
lock-
washers
(7)
c. Wiring
Reconnect and remove
tags.
d. Filter
Remove.
breather
(4)
e. Reservoir
Refill.
The reservoir
(3)
holds 10 gallons
(37.85 liters)
of hydraulic
fluid.
f.
Initial
Refer to step 7.
start-up
g. Filter
Replace.
breather
(4)
3-3238


 