4-5. GENERAL (Continued).
Table 4-6. Air Conditioner Abnormal Operating Pressures/Temperatures - Troubleshooting (Continued).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. High crankcase temperature (exceeds 105180 at seal housing).
-
F
Step 1. Clogged liquid line strainer.
Pump down. Remove and clean strainer.
Step 2. Excessive superheat.
Reset thermal expansion valve(s) to 810 superheat.
-
F
Step 3. Leaking compressor suction or discharge valves.
Pump down, remove cylinder heads and examine suction and discharge valves. Replace if
necessary.
Step 4. Discharge temperature exceeds 240 .
F
By-pass heat interchanger.