Tweet |
Custom Search
|
|
|
||
TM 55-1905-220-14-8
4-5. GENERAL (Continued).
Table 4-21. Urinal Discharge Valve Troubleshooting.
NOTE
Refer to paragraph 4-15 for maintenance instructions.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Vacuum leak between inlet or outlet ports.
Step 1. Stuck float.
Open top of unit and re-position float so that
it works freely.
Step 2. - Worn or damaged seal.
Replace seal.
2. Vacuum leak at top cover.
"O" ring leaking or check valve leaking.
Replace "O" ring or rubber check.
3. Leak in body of assembly.
Cracked body.
Loosen hose clamps, remove, and replace assembly.
4-66
|
||