Custom Search
 
  
 
TM 55-1905-220-14-8
4-7.5. MAGNETO ASSEMBLY - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
ADJUSTMENT (Con')
t
(2) The breaker point surface becomes pitted after a long period of service and after
a long period of idleness the surfaces may become oxidized. Both conditions
prevent proper operation of the magneto and result in a faulty spark at the spark
plug. To function properly, the breaker point surfaces must be clean and smooth,
and may be cleaned in the following manner:
(a) Carefully spread the points with a small screw driver, and insert a point
dresser. A strip of fine sandpaper folded back to back may be used for a
point dresser.
(b) Release points and work point dresser up and down until point surfaces are
clean and smooth. If points do not clean up easily, replace the points.
(c) Insert a strip of clean, stiff paper, and remove any traces of corrosion or point
dressing material which may have adhered to the point surfaces.
4-165


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business