TM 55-1905-220-14-8
4-19.1. SEWAGE DISCHARGE PUMP - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
11.
Pump
IMPORTANT - Close ball valve on input to pump.
Failure to do so would result in draining of sewage
tank.
a. Nuts (25),
Remove.
and screws
(26)
b. Nuts (48),
Remove.
and screws
(49)
c.
Nuts (55),
Remove.
and screws
(56)
d. Nuts (57),
Remove.
and screws
(58)
e. Coupling
Remove.
(59), and
key (60)
INSTALLATION
12.
a. Coupling
Install.
(59), and
key (60)
b. Screws (58),
Install.
and nuts
(57)
c.
Screws (56),
Install.
and nuts
(55)
d. Screws (49),
Install.
and nuts
(48)
4-704
|
|