Tweet |
Custom Search
|
|
|
||
TM 55-1905-220-14-9
4-66.1. TANK LEVEL INDICATION - RECEIVER - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
11. Connector
a. Incoming
Disconnect.
plug or
cable (27
receptacle
or 28)
b. Screws (29),
Remove.
(30)
c.
Receptacle
Withdraw from
(31, 32 or
housing.
33) and
gasket (34)
d. Wiring
Unsolder.
Refer to schematic
on page 4-1398.
4-1405
|
||