4-27. RAMP HOISTING ASSEMBLY (Continued).
LOCATION/ITEM
ACTION
REMARKS
SERVICE (Cont)
i.
If air persists in system,
check suction lines for
leaks.
j.
Wipe any excess oil from tank
and hoses with a clean dry
cloth.
12. Filter
a. Observe the filter condition
(Return Line)
indicator (1) to see if it is
reading in the red.
b. Charge the elements (2) only
when ramp hoist pumps are not
in operation.
c.
Unscrew housing (3) from head
(4).