4-33.
HYDRAULIC STARTING SYSTEM (Continued).
Location/Item
Action
Remarks
SERVICE
1. Reservoir and
a. Close valves (1) and (2)
Filter
and open drain (3) to
check cleanliness of fluid
in reservoir (4). Fluid
should be clear.
b. Close drain and disconnect
hoses at check valves (5)
and (6).
c.
Remove filter (7) and replace
element.
NOTE
Filter element should be changed every 2000 hours
of operation.
d. Install filter and connect
hoses at check valves.
e. Open valves (1) and (2).
f.
Remove filler and vent cap
(8) and fill reservoir.
Replace cap.
4-120


 