TM 55-1905-221-14-1
4-35.
HYDRAULIC STARTING SOLENOID VALVE (Continued).
Location/Item
Action
Remarks
INSPECTION (Cont)
b. Check hydraulic lines for
cracks, breaks, leaks or
other defects.
REMOVAL
2. Solenoid
a. Close accumulator valves.
See figure
Valve
2-12.
The oil pressure in the system must be released prior to servicing the hand pump or any other components
of the system, to prevent possible injury to personnel or damage to equipment.
b. Relieve pressure in lines
See figure
by opening system relief
1-8.
valve.
c.
Remove and tag electrical
connections (1).
4-126
|
||