4-54.
FRESH WATER PUMP (Continued).
Location/Item
Action
Remarks
INSPECTION
1. Fresh Water
Inspect pump and around water
Pump
inlet elbow for leaks, cracks
or other damage or defects.
REMOVAL
2. Fresh Water
a. Drain the cooling system.
Pump
b. Remove bolt (1), washer (2),
and remove water inlet elbow
(3) from pump (4).
c.  Remove bolts and lockwashers
that attach pump outlet
flange to cylinder block.
Remove flange and packing ring.
d. Remove three bolt and seal
assemblies (5) that attach
pump to blower assembly.
Use wrench (J4242) to loosen
inner bolt.
e. Withdraw pump and remove
and discard gasket.
INSTALLATION
3. Fresh Water
a. Place pump outlet flange
Pump
over pump outlet with flat
side of flange facing the
pump body. Slip packing
ring over pump outlet and
next to flange.
4-208


 