Custom Search
 
  
 
TM 55-1905-221-14-3
6-5.2.
HYDRAULIC PUMP DRIVE COMPONENTS (Continued).
LOCATION/ITEM
ACTION
REMARKS
CLEANING
2. Drive
Components
Dry cleaning solvent, P-D-680, used to clean parts, is potentially dangerous to personnel
and property. Avoid repeated or prolonged skin contact. Do not use near open flame or
excessive heat. Flash point of solvent is 100-138 (3859 ).
F
-
C
Clean all parts in cleaning
solvent, Fed. Spec. P-D-680 and
dry thoroughly.
INSPECTION
3. Drive
a. Inspect teeth on adapter
Components
gear, drive plate and drive
coupling for nicks or chipped
teeth.
b. Inspect other parts for
cracks, breaks, or other
damage.
REPAIR
4. Drive
Replace damaged or defective
Components
parts as required.
6-30


 