TM 55-1905-221-14-3
6-19.
STARTING MOTORS (ELECTRIC) (Continued).
LOCATION/ITEM
ACTION
REMARKS
CLEANING (Cent)
b. General cleaning of the
commutator is done with
No. 0/2 flint paper (Federal
Specification P-P-111).
c.
The field coils should be
cleaned by wiping with a
clean, dry cloth. Be
careful in handling the
windings to avoid breaking
or weakening the connecting
straps between windings.
OVERHAUL
7. Starting
a. Replace brushes.
Motor
b. The brush springs should
have sufficient tension to
provide the proper pressure
between the brushes and
commutator after the unit
is assembled. This may be
checked by placing the
armature and commutator end
frame together in their
normal operating position.
and then placing the
brushes in their holders
with the springs in place
so that the tension of the
springs against the brushes
can be measured with a
spring gauge. Correct
spring tension should be 36
to 40 ounces (10 to 11 n).
Replace springs if tension
is not correct.
6-216