Custom Search
 
  
 
TM 55-1905-221-14-4
6-31. FUEL INJECTORS (Continued).
LOCATION/ITEM
ACTION
REMARKS
TESTING (Cont)
(b) Run the injector
for 30 seconds to
purge all air
that may be in
system. Press
fuel flow start
button to start
flow of fuel
into vial. The
automatically stop
fuel flow after
1000 strokes.
(c) After fuel stops
flowing into vial,
pull the rack
out to the NO FUEL
position, turn off
reset the counter
and observe the
vial reading.
(d) If the injector
fuel output in the
vial does not fall
within a minimum
of 30 cc (cubic
centimeters) or
maximum of 36cc,
the injector
is defective and
must be repaired.
DISASSEMBLY/OVERHAUL
2. Filter Cap
a. Support injector assembly
and Element
upright in fixture tool
as shown.
6-560


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business