Custom Search
 
  
 
TM 55-1905-221-14-4
6-33. RAW WATER PUMP (Continued).
LOCATION/ITEM
ACTION
REMARKS
DISASSEMBLY (Cont)
v. Remove bolts (27) from drive
plate.
w. Remove drive plate (28) and
retaining plate (29) from
flywheel housing.
x. Remove drive coupling (30)
Discard
from drive plate (28).
coupling.
y Remove gasket (31).
Discard.
CLEANING
3. Water Pump
WARNING
Dry cleaning solvent, P-D-680, used to clean parts, is potentially dangerous to personnel and
property. Avoid repeated or prolonged skin contact. Do not use near open flame or excessive
heat. Flash point of solvent is 100- 138 (38- 59 ).
F
C
Clean all parts with cleaning
solvent Fed. Spec. P-D-680.
6-598


 