2-5.2  Communication Equipment.  Operating instructions for the communication equipment are covered in the
pertinent technical manual Refer to Appendix A.
2-5.3 Navigation Equipment.  The Remote Magnetic Heading System (RMHS) consists of an  induction compass
transmitter and a heading indicator. The induction compass transmitter, which senses the vessel's heading relative to
the magnetic NORTH, is located on the mast support.  The heading indicator, which indicates the vessel's heading as
determined by the induction compass transmitter, is located in the pilothouse control console.  To engage the RMHS,
place the RMHS switch (para 2-1, item 38) to the ON position.
2-5.4 Oil/Water Separator and Bilge Pumping System. Normal operation of the bilge pumping system is through the
Oil/Water Separators (OWS).  The engines must be operating to provide electric power to the electric motor which
drives the Oil/Water Separator (OWS) pump. Use the accompanying procedures to perform the following functions.
a.
Empty Bilges.
(1)  Open bilge manifold valve of compartment that needs emptying.
(2)  Open valves V-l, V-5, V-9, V-ll and V-12.
(3)  Close valves V-2, V-3, V-4, V-6, V-7 and V-10.
(4)  Turn on OWS pump at control panel (refer to TM 55-2090-201-14&P).
(5)  Turn off OWS pump and close V-1 when the bilge compartment is empty.