TM 55-1905-222-14
d.
Pump oil from primary and secondary stage separator to holding tank (refer to TM 55-2090-201-14&P).
c.
Pump oil from holding tank to another holding tank ashore.
(1) Attach one end of hose to coupling at V-3 and the other end to a used oil container at a shore
installation.
(2) Open valves V-3 and V-6.
(3) Close valves V-1, V-2, V-4, V-5, V-7, and V-10.
(4) Turn on OWS pump at control panel (refer to TM 55-2090-201-14&P).
(5) Turn off OWS pump when you are done and close V-3 and V-6.
Change 6