Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
STEERING SYSTEM - Continued
6. RUDDER ANGLE INDICATOR DOES NOT RESPOND.
Step 1.
Check to see if RAI switch is OFF.
Turn RAI switch to ON.
Step 2.
Check to see if transmitter connecting linkage is obstructed.
Remove obstruction.
Step 3.
Check to see if RAI fuses are blown.
Notify unit maintenance.
Step 4.
Check to see if RAI switch is defective.
Notify unit maintenance.
Step 5.
Check to see if transmitter connecting linkage is damaged.
Notify direct support maintenance.
7. RUDDER ANGLE INDICATOR READING INCORRECT.
Step 1.
Check to see if transmitter (follow-up unit) potentiometer is maladjusted.
Notify direct support maintenance.
Step 2.
Check to see if transmitter is defective.
Notify direct support maintenance
BILGE SYSTEM
1. OIL WATER SEPARATOR (OWS) PUMP FAILS TO DELIVER WATER
Step 1.
Check to see if OWS pump motor control is OFF at the control panel
Turn on pump motor control
3-12


 