Custom Search
 
  
 
TM 55-1905-222-14
MAINTENANCE OF STARTING SYSTEM
3-13
SERVICE STARTING SYSTEM RESERVOIR AND FILTERS.
INITIAL SETUP
Tools:
Equipment Conditions:
Tool Kit, Mechanic's Rail
Engine shut down
and Marine
Materials/Parts:
General Safety Instructions
Hydraulic Fluid
Observe warning stenciled on ramp/
Item 24, Appendix E
starting system reservoir
Cleaning Solvent
Item 17, Appendix E
Filter Element
P/N FE 200575
'O' Ring
P/N GA 100201
NOTE
Maintenance Instructions for starting system reservoir
are similar to that of the ramp system reservoir (para.
1. REMOVE 40 MICRON T-TYPE
FILTER HOUSING
WARNING
The starting system is a high pressure hydraulic system.
Relieve pressure in system by opening the accumulator
blowdown valve before servicing.  Failure to comply
may result in injury to personnel.
NOTE
Have a container ready to catch oil from the filter.
a
Close suction line shutoff valve (1).
b
Unscrew filter housing (2) from filter
cap (3).
c. Remove gasket (4), filter element
(5), seat guide (6) and spring (7)
from filter housing.
3-42


 